Trades on this job
Concrete Not named yet. The concrete sub shows up here when the shoring or post tension permit is pulled, usually months before the pour. The trades below are the permits pulled so far, often on the sales gallery or the existing site.
Fire protection & life safety
Fire suppression permit: B M CONSULTING SERVICES INC, under CP-2025-005201 · EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE 11 SPRINKLER HEADS TO ACCOMMODATE NEW FLOOR PLANS FOR DOGGIE WASH · 2 permits
Dec 5, 2025 to Dec 9, 2025
Electrical
Electrical permit: FIRST ELECTRIC LIGHTING AND DESIGN, under CP-2025-005201 · ***Per the building permit, work area under 2,000 sqft, no review required*** Life Safety - Supply, Wire & Install (3) Emergency Lights - Supply, Wire & Install (2) Emergency Exit Signs W/ Lights Note: Placement Per Plans Provided General Provisions - Provide, Wire & Install As Follows: Rm101: Adoption- (1) Standard White Outlet; (1) 2x4 Lay In LED Troffer Light; (1) White Toggle Switch Rm102: Corridor- (1) Standard Wh · 2 permits
Dec 5, 2025 to Dec 24, 2025
Plumbing
Plumbing permit: GREGORY ROSSI PLUMBING & HEATING LLC, under CP-2025-005201 · Install plumbing system to pick up the following fixtures all on 1st fl toilet, lav, mop sink, 2 dog washing tables, washer box, water heater · 2 permits
Dec 5, 2025 to Feb 2, 2026
Electrical
Electrical permit: City Lights electric llc, under CP-2026-000998 · INSTALL NEW MDPA 100A PANEL FED FROM EXISTING MDP as per plan Rough and trim the entire area as per plan Install light fixtures, outlets, emergency lighting and exit signs Install tele/data wiring Wire all HVAC equipment as per plan Grounding as per 2017 NEC Existing fire alarm system to be remain · 2 permits
Apr 20, 2026 to Jul 17, 2026
HVAC
Mechanical permit: ANGEL HEATING & COOLING INC, under CP-2026-000998 · FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND ASSOCIATED DUCTWORK TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. · 2 permits
Apr 20, 2026 to Jun 2, 2026
Plumbing
Plumbing permit: Honest Plumbing & Heating LLC, under CP-2026-000998 · Installation of 6 Hair sinks, 2 water heaters, 2 toilets, two lavy sinks, 1 kitchenette sink, 1 hvac hub drain · 2 permits
Apr 20, 2026 to Jul 16, 2026
Fire protection & life safety
Fire suppression permit: Oliver Sprinkler Co., Inc, under CP-2026-000998 · EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (27) sprinkler heads to accommodate interior alterations · 2 permits